0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CTM 1X2- 12DC

CTM 1X2- 12DC

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    Res Thin Film 0805 149K Ohm 0.1% 0.1W(1/10W) ±25ppm/C Molded SMD Paper T/R

  • 数据手册
  • 价格&库存
CTM 1X2- 12DC 数据手册
https://www.phoenixcontact.com/us/products/2838597 Surge protection plug - CTM 1X2- 12DC - 2838597 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) LSA-PLUS plug with protection for conductor pairs in floating signal circuits. Nominal voltage: 12 V DC The illustration shows version CTM 1x2- 24 DC Product Features ■ ■ ■ ■ ■ The CTM 10-MAG surge protection magazine can be freely fitted with various protective plugs Can be used in LSA-PLUS disconnect and control strips or CT-TERMIBLOCK Space-saving LSA-PLUS connection technology Typical installation locations include marshalling distributors Modular compact protection for high-density networks Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 10.03 g Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 21 mm Width 9.5 mm Depth 53.5 mm Ambient conditions Ambient temperature (operation) -25 °C ... 75 °C Degree of protection IP20 03/08/2016   Page 1 / 5 https://www.phoenixcontact.com/us/products/2838597 Surge protection plug - CTM 1X2- 12DC - 2838597 Technical data General Housing material PA Flammability rating according to UL 94 V0 Color black Standards for cearances and creepage distances DIN VDE 0110-1 IEC 60664-1 Overvoltage category II Degree of pollution 2 Mounting type On CT-TERMIBLOCK and LSA-PLUS disconnect strip Type LSA-PLUS module Number of positions 2 Direction of action Line-Line & Line-Earth Ground Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.10 Protective circuit IEC test classification B2 C1 C2 C3 D1 VDE requirement class B2 C1 C2 C3 D1 Nominal voltage UN 12 V DC Maximum continuous voltage UC ± 15 V DC 10 V AC Maximum continuous voltage UC (wire-wire) ± 15 V DC 10 V AC Maximum continuous voltage UC (wire-ground) 72 V DC Nominal current IN 380 mA (25 °C) Operating effective current IC at UC ≤ 5 µA Residual current IPE ≤ 2 µA Nominal discharge current In (8/20) µs (Core-Core) 5 kA Nominal discharge current In (8/20) µs (Core-Earth) 5 kA Total surge current (8/20) µs 10 kA Total surge current (10/350) µs 2.5 kA 03/08/2016   Page 2 / 5 https://www.phoenixcontact.com/us/products/2838597 Surge protection plug - CTM 1X2- 12DC - 2838597 Technical data Protective circuit Max. discharge current Imax (8/20) µs maximum (Core-Earth) 10 kA (in total) Nominal pulse current Ian (10/1000) µs (Core-Core) 100 A Nominal pulse current Ian (10/1000) µs (Core-Earth) 100 A Impulse discharge current (10/350)˽µs, peak value limp 1 kA Output voltage limitation at 1 kV/µs (Core-Core) spike ≤ 45 V Output voltage limitation at 1 kV/µs (Core-Earth) spike ≤ 700 V Output voltage limitation at 1 kV/µs (Core-Core) static ≤ 25 V Output voltage limitation at 1 kV/µs (Core-Earth) static ≤ 700 V Residual voltage at In (conductor-conductor) ≤ 22 V Residual voltage at In (conductor-ground) ≤ 45 V Residual voltage with Ian (10/1000)µs (conductor-conductor) ≤ 25 V Residual voltage with Ian (10/1000)µs (conductor-ground) ≤ 25 V Voltage protection level Up (core-core) ≤ 40 V (C2 - 10 kV/5 kA, spike) ≤ 25 V (C2 - 10 kV/5 kA, static) ≤ 25 V (C3, 7.5 kV/100 A) Voltage protection level Up (core-ground) ≤ 700 V (C2 - 10 kV/5 kA, spike) ≤ 45 V (C2 - 10 kV/5 kA, static) ≤ 700 V (C3, 7.5 kV/100 A, spike) ≤ 20 V (C3, 7.5 kV/100 A, static) Response time tA (Core-Core) ≤ 1 ns Response time tA (Core-Earth) ≤ 100 ns Input attenuation aE, sym. 0.3 dB (≤ 400 kHz) Cut-off frequency fg (3 dB), sym. in 100 Ohm system 1.2 MHz Capacity (Core-Core) 1.5 nF (f=1 MHz / VR= 0 V) Resistance in series 3.3 Ω 10 % 3.3 Ω Surge protection fault message None Impulse durability (conductor-conductor) C2 (4 kV/2 kA) C3 - 100 A B2 - 4 kV/100 A Impulse durability (conductor-ground) C2 - 4 kV/2 kA C3 - 100 A B2 - 4 kV/100 A D1 - 1 kA Alternating current carrying capacity (conductor-ground) 5A-1s Connection data 03/08/2016   Page 3 / 5 https://www.phoenixcontact.com/us/products/2838597 Surge protection plug - CTM 1X2- 12DC - 2838597 Technical data Connection data Connection method can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips Connection type IN COMTRAB plug-in system Connection type OUT COMTRAB plug-in system Connection method LSA-PLUS Connection, equipotential bonding Connection method Spring contact Standards and Regulations Standards/regulations IEC 61643-21 Classifications eCl@ss eCl@ss 4.0 27140201 eCl@ss 4.1 27130801 eCl@ss 5.0 27130801 eCl@ss 5.1 27130801 eCl@ss 6.0 27130807 eCl@ss 7.0 27130807 eCl@ss 8.0 27130807 eCl@ss 9.0 27130807 ETIM ETIM 2.0 EC000943 ETIM 3.0 EC000943 ETIM 4.0 EC000943 ETIM 5.0 EC000943 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 Approvals Approvals 03/08/2016   Page 4 / 5 https://www.phoenixcontact.com/us/products/2838597 Surge protection plug - CTM 1X2- 12DC - 2838597 Approvals Approvals UL Listed / EAC Ex Approvals Approvals submitted Approval details UL Listed  EAC  Drawings Dimensional drawing 18,5 Circuit diagram 9,4 1 1' IN 52,4 38 OUT 2 2' Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 03/08/2016   Page 5 / 5
CTM 1X2- 12DC 价格&库存

很抱歉,暂时无法提供与“CTM 1X2- 12DC”相匹配的价格&库存,您可以联系我们找货

免费人工找货